AbOliGo Laboratory
Single-Cell & Feature Barcoding

Custom antibody-oligo conjugates forCITE-seq and 10x Feature Barcoding

We conjugate the exact clone you have validated to a feature-barcode oligo that matches your 10x chemistry. QC-released for consistent signal, from 20 µg of antibody, in days.

Get a CITE-seq Conjugate Quote

The catalog panel only gets you so far…

CITE-seq, cell hashing and 10x Feature Barcoding all rely on the same reagent: an antibody labeled with a barcoded oligo, known as an antibody-derived tag (ADT). For many studies, the ready-made version has two problems.

The clone you need isn't in the catalog. Ready-made panels come with a fixed list of markers and clones. If your target calls for a different clone, or an antibody you have already validated elsewhere, the fixed panel can't supply it.

Conjugating it yourself is hard to keep consistent. The number of oligos on each antibody affects the signal, and both too few and too many compromise it. Getting the degree of labeling right, and repeating it across a whole panel, is difficult to do reliably by hand.

Under- or over-labeling an antibody with oligos can cost you a marker across the entire run.

Your clone, your chemistry, QC-released

A custom ADT service for people building their own panels.

Your exact clone

Conjugate the antibody you have already validated, or a clone no commercial panel offers. Any host species and isotype, monoclonal or recombinant.

QC-released for signal

We set the number of oligos per antibody to the level that gives the best signal, and we measure it. Purity and free oligo are checked too, so one batch matches the next.

Days, from 20 µg

Test a candidate clone before you commit a large amount of antibody. We work at small scale, so a single custom order does not wait behind a production batch.

Matched to the 10x chemistry you already run

The capture sequence on your ADT has to match your kit. We make it in the format your kit uses, so it works with your existing library prep.

3′ Feature Barcoding

Single Cell 3′ v3.1 and GEM-X 3′ v4

Feature-barcode capture sequence, compatible with TotalSeq-B workflows.

5′ Immune Profiling

Single Cell 5′ / V(D)J

Capture sequence complementary to the 5′ template-switch oligo, compatible with TotalSeq-C workflows.

Poly-A capture

Original CITE-seq workflows

Oligo-dT-capturable handle, compatible with TotalSeq-A workflows.

Running a custom barcode set? Send us your oligo design and we will conjugate to it.

We control the degree of labeling, so your signal is reproducible

How many oligos sit on each antibody has a large effect on sensitivity. We set that number deliberately and confirm it before we ship.

Figure 1: dual DNA and protein gel staining showing tunable degree of labeling for AbOliGo antibody-oligonucleotide conjugates.
Figure 1. AbOliGo's conjugation workflow enables controlled tuning of the degree of labeling (DoL). Adjusting the conjugation conditions produces an increased gel shift, consistent with higher oligo loading for both 15-mer (lanes 3 to 5) and 32-mer oligos (lanes 6 to 8). Dual gel staining (DNA and protein) confirms both antibody and oligo content, while the absence of unbound oligo demonstrates effective post-conjugation purification. Ab = antibody alone.

One reagent, across the method family

The same barcoded antibody is used for surface, nuclear, chromatin and multi-modal single-cell readouts. Tell us the method and we will make the conjugate to suit.

CITE-seq

Surface protein plus transcriptome from the same cell, read out alongside your gene expression library.

Cell hashing & multiplexing

Hashtag oligos (HTOs) against ubiquitous markers to pool samples in one run and demultiplex by tag.

inCITE-seq

Intranuclear and transcription-factor profiling in fixed, permeabilized nuclei, where conjugate behavior is especially demanding.

ASAP-seq & ECCITE-seq

Protein with chromatin accessibility, or five-modality readouts including clonotype and CRISPR guides.

How a custom ADT project runs

1

Define the tag

Tell us your antibody, your chemistry (3′, 5′ or poly-A), and your barcode design. We set scope, capture format, degree of labeling and QC release criteria.

2

Conjugation & QC

We conjugate and purify your ADT at µg scale, then validate degree of labeling, purity and free oligo against the agreed spec.

3

Dispatch & re-order

Your QC-released tag ships assay-ready with a release report. Re-orders use the same process and criteria, so panels stay consistent run to run.

Who orders custom ADTs from us

  • Single-cell immunologists building panels with clones no catalog carries
  • Core facilities supplying multiple PIs who need consistent, schedulable batches
  • Multi-omics and spatial groups who have outgrown off-the-shelf ADT panels
  • Labs running fixed-nuclei or intranuclear workflows, where conjugate quality matters most
  • Method developers scoping a reagent before scaling a study
Days
Not weeks
20 µg
Minimum starting material
100%
QC-released
3′ & 5′
Chemistry compatible

Get the clone your panel actually needs

Tell us your antibody, your chemistry and your barcode, and we will scope a QC-released ADT that works in your run.

Request a CITE-seq conjugate quote

Share your antibody, target method and chemistry (3′, 5′ or poly-A) and we will reply with scope, timeline and pricing.

By submitting, you agree to be contacted by AbOliGo about your enquiry.